P2686 – Actuator Supply Voltage C Circuit High

The high case of supply C concerns voltage that should not be there: the rail stays live although the controller has turned it off. Causes are an internal high-side switch that no longer opens or an outside wire touching battery positive. GM's 2023 and 2024 TCM tables run this check during shutdown. With output 7 disabled, a reading above 70 % of battery voltage counts as a shorted switch; the module keeps that finding in permanent memory and reports it once restarted. Battery voltage must stay within 1.5 V during the test, and GM files it as Type B: two failing trips before the lamp lights. Ford lists P2686 as the shorted-switch fault of high side driver 7 in its 2024 TR9070 table and also in the Boss 302S code list. The solenoids can no longer be switched off safely, so a limp mode is likely.

Possible causes

Possible symptoms

Diagnosis

Use a compatible scan tool to confirm the code and check related codes and live data. Inspect the relevant wiring, connectors, power, ground and sensor signals using the vehicle manufacturer’s wiring diagram and service specifications. Do not replace a component based on the code alone.

Related DTC codes

Search this code in DTC Search

Generic OBD-II reference only. Manufacturer-specific definitions, test values and repair procedures can vary by vehicle. Verify with vehicle-specific service information.