P0883 – TCM Power Input Signal High
The TCM power input codes watch the supply voltage of the gearbox module or of its solenoid supply. Without a proper supply all solenoids go dead and the gearbox falls back to its hydraulic emergency gear with maximum line pressure: a fixed gear, harsh engagement, no shifting. Ford's external gearbox modules check a window of 9 to 16 V; GM reports the same under P0562/P0563. P0883 means the supply is too high: Ford sets it above 16 V, continuously and with MIL; GM's counterpart P0563 sets at 18 V. Typical triggers are a failed alternator regulator or a jump start with 24 V. Overvoltage endangers the output stages, so the module may switch the solenoids off.
Possible causes
- Alternator voltage regulator faulty (overcharging)
- Jump start with 24 V or charger in boost mode
- Poor battery ground, regulator measures wrongly
- Module measurement faulty
Possible symptoms
- MIL on
- Charging warning or unusually bright lights
- Overvoltage codes in other modules
Diagnosis
Use a compatible scan tool to confirm the code and check related codes and live data. Inspect the relevant wiring, connectors, power, ground and sensor signals using the vehicle manufacturer’s wiring diagram and service specifications. Do not replace a component based on the code alone.
Related DTC codes
Search this code in DTC Search
Generic OBD-II reference only. Manufacturer-specific definitions, test values and repair procedures can vary by vehicle. Verify with vehicle-specific service information.