P2671 – Actuator Supply Voltage B Circuit High

P2671 points to voltage on the second actuator supply when the controller has switched it off, so the line is fed from outside or the switch inside the module no longer opens. The solenoids on that supply can then no longer be de-energised as a group, which defeats the failsafe. GM tests this mostly at start-up or shut-down: in the 16OBDG08 TCM tables a short to power below 0.5 ohm is detected during initialisation with the driver off; the 2023 TCM checks at power-down whether the supply stays above 70 % of battery voltage, stores the result and sets the code at the next start as Type B. GM's hybrid HPC1 table of 2019 likewise rates it Type B. Ford's 2014 list contains P2671 without MIL. P2669 is the open circuit, P2670 the short to ground.

Possible causes

Possible symptoms

Diagnosis

Use a compatible scan tool to confirm the code and check related codes and live data. Inspect the relevant wiring, connectors, power, ground and sensor signals using the vehicle manufacturer’s wiring diagram and service specifications. Do not replace a component based on the code alone.

Related DTC codes

Search this code in DTC Search

Generic OBD-II reference only. Manufacturer-specific definitions, test values and repair procedures can vary by vehicle. Verify with vehicle-specific service information.