P2685 – Actuator Supply Voltage C Circuit Low
P2685 means the third actuator supply rail sags while it is switched on, almost always because the line or one of the loads it feeds has a path to ground. Unlike the open and switch faults of this rail, GM's 2023 and 2024 TCM tables check this one continuously during operation: if the voltage at high-side output 7 falls below a share of the supply, or the averaged output current runs too high, a timer counts up and the fault is confirmed after 60 ms. Battery voltage must lie between 8.75 and 18 V, the engine must not be cranking, and the test is suspended when P0882 or P0883 is present; GM rates it Type A. Ford's 2024 summary lists P2685 as the shorted-load fault of high side driver 7 in the TR9070 dual-clutch unit. The protected output switches off and the transmission falls back to a failsafe mode.
Possible causes
- Supply wire chafed through and touching ground
- Shorted solenoid coil on this rail drawing excess current
- Weak battery or charging fault pulling the whole supply down
Possible symptoms
- MIL on during the same trip
- Failsafe gear, no normal shifting
- Blown fuse possible on the transmission supply
Diagnosis
Use a compatible scan tool to confirm the code and check related codes and live data. Inspect the relevant wiring, connectors, power, ground and sensor signals using the vehicle manufacturer’s wiring diagram and service specifications. Do not replace a component based on the code alone.
Related DTC codes
Search this code in DTC Search
Generic OBD-II reference only. Manufacturer-specific definitions, test values and repair procedures can vary by vehicle. Verify with vehicle-specific service information.