P24B8 – EVAP System Leak Detection Pump Pressure Sensor Circuit
P24B8 is the general circuit fault of the pressure sensor that sits inside an evaporative leak check module together with the pump and the switching valve. The sensor gets a 5 V reference from the engine computer and reports canister-side pressure during the engine-off leak test. No manufacturer documents P24B8 publicly; GM, Mitsubishi and Subaru use the more specific P24B9 to P24BB for this sensor. CARB requires such EVAP input components to be checked for circuit faults and implausible values. With this fault present, the leak test cannot be trusted and will not complete, so the EVAP readiness flag stays open. Typical findings are a broken reference or ground wire, a corroded module plug or a failed module.
Possible causes
- Open or shorted 5 V reference, ground or signal wire to the leak check module
- Corroded or loose connector at the leak check module near the canister
- Pressure sensor inside the leak check module failed
- Engine control module does not supply the sensor reference
Possible symptoms
- Malfunction indicator lamp on
- EVAP readiness monitor does not complete
Diagnosis
Use a compatible scan tool to confirm the code and check related codes and live data. Inspect the relevant wiring, connectors, power, ground and sensor signals using the vehicle manufacturer’s wiring diagram and service specifications. Do not replace a component based on the code alone.
Related DTC codes
Search this code in DTC Search
Generic OBD-II reference only. Manufacturer-specific definitions, test values and repair procedures can vary by vehicle. Verify with vehicle-specific service information.