P2400 – EVAP System Leak Detection Pump Control Circuit/Open

P2400 is stored when the engine computer finds the drive line of the evaporative leak detection pump open, so the pump cannot be switched for the tank leak test. GM's tables for the sealed fuel system of the Volt (2011, 2016) compare the commanded and actual driver state and treat a low voltage in the off state, equal to more than 200 kOhm to ground, as an open; 20 failed samples out of 25 at 250 ms each set a Type B code. VW's 2014 Golf data book flags a signal voltage of roughly 4.4-5.6 V. Toyota names P2400 with failure types 7E/7F on A25A engines, and VW traced P2400 on the 2011-2014 Touareg 3.6 to coolant entering the pump's vacuum line. P2401 and P2402 are the short-circuit siblings. The leak test cannot run; the car drives normally.

Possible causes

Possible symptoms

Diagnosis

Use a compatible scan tool to confirm the code and check related codes and live data. Inspect the relevant wiring, connectors, power, ground and sensor signals using the vehicle manufacturer’s wiring diagram and service specifications. Do not replace a component based on the code alone.

Related DTC codes

Search this code in DTC Search

Generic OBD-II reference only. Manufacturer-specific definitions, test values and repair procedures can vary by vehicle. Verify with vehicle-specific service information.