P24BA – EVAP System Leak Detection Pump Pressure Sensor Circuit Low
P24BA reports that the voltage from the leak check module's pressure sensor has fallen below the lowest value a working sensor can produce. In GM's ELCP tables (2018 Volt) the limit is 0.70 V, about 14 % of the reference or roughly 47 kPa absolute, with 640 failures in 800 samples taken every 12.5 ms; the check runs whenever the controller is awake and is Type B. Mitsubishi's 2023 Outlander PHEV sets P24BA when the signal stays under 0.1 V for 2 s. Subaru asks technicians to clear P24BA before chasing P2404 in the ELCM. A low signal mostly means a lost 5 V reference, a signal wire shorted to ground or a dead sensor. P24BB is the high-side counterpart; the leak test is suspended until the fault is gone.
Possible causes
- Sensor signal wire shorted to ground
- 5 V reference open or pulled down by another sensor on the same supply
- Pressure sensor inside the leak check module failed
Possible symptoms
- Malfunction indicator lamp on
- EVAP leak test not run
Diagnosis
Use a compatible scan tool to confirm the code and check related codes and live data. Inspect the relevant wiring, connectors, power, ground and sensor signals using the vehicle manufacturer’s wiring diagram and service specifications. Do not replace a component based on the code alone.
Related DTC codes
Search this code in DTC Search
Generic OBD-II reference only. Manufacturer-specific definitions, test values and repair procedures can vary by vehicle. Verify with vehicle-specific service information.