P24BB – EVAP System Leak Detection Pump Pressure Sensor Circuit High
P24BB is stored when the leak check module's pressure signal climbs above the top of its usable range. GM uses 4.85 V, about 97 % of the reference or roughly 120 kPa, again with 640 of 800 samples and Type B; the limit appears unchanged from the 2018 Volt up to GM's 2025 table 25OBDG03A for conventional ELCP systems. Mitsubishi's 2023 Outlander PHEV flags the code above 4.9 V lasting 2 s. Subaru lists P24BB with P24BA and P24B9 as faults to clear first when P2404 appears. A reading pinned high usually comes from an open ground, a signal wire touching a voltage source or an internal sensor fault, rarely from real pressure. P24BA covers the low side; P24B9 a signal that stays in range but disagrees with barometric pressure.
Possible causes
- Open sensor ground or signal wire, letting the input float high
- Signal wire shorted to the 5 V reference or battery voltage
- Pressure sensor inside the leak check module failed
Possible symptoms
- Malfunction indicator lamp on
- EVAP leak test not run, readiness incomplete
Diagnosis
Use a compatible scan tool to confirm the code and check related codes and live data. Inspect the relevant wiring, connectors, power, ground and sensor signals using the vehicle manufacturer’s wiring diagram and service specifications. Do not replace a component based on the code alone.
Related DTC codes
Search this code in DTC Search
Generic OBD-II reference only. Manufacturer-specific definitions, test values and repair procedures can vary by vehicle. Verify with vehicle-specific service information.