P0D17 – Battery Charging System A High Voltage Interlock Circuit Low
P0D17 means the sensed voltage of the charging HVIL loop is too low. GM documents the check for the Chevrolet Volt (2011, 2014) and the Cadillac ELR: while the module sources 5 V into the loop, a sensed value under 30 % of the reference in two samples out of two at 12.5 ms sets the code as Type A, with the MIL on after one trip. A low reading suggests a path to ground or leakage somewhere in the loop wiring, or a fault in the measuring stage of the module. Because the test only runs with the source switched on, it typically shows up around charging. The interlock of battery and drive has its own code, P0A0C. P0D18 is the high counterpart, P0D15 the open loop. With an implausible loop the car refuses to charge.
Possible causes
- Interlock wire chafed and touching ground
- Moisture or dirt in an interlock connector causing leakage
- Fault in the interlock source or measuring circuit of the control module
Possible symptoms
- Malfunction indicator lamp after one trip (GM Type A)
- Charging refused
Diagnosis
Use a compatible scan tool to confirm the code and check related codes and live data. Inspect the relevant wiring, connectors, power, ground and sensor signals using the vehicle manufacturer’s wiring diagram and service specifications. Do not replace a component based on the code alone.
Related DTC codes
Search this code in DTC Search
Generic OBD-II reference only. Manufacturer-specific definitions, test values and repair procedures can vary by vehicle. Verify with vehicle-specific service information.