P0D15 – Battery Charging System A High Voltage Interlock Circuit/Open
P0D15 reports an open high-voltage interlock loop in charging system A. This low-voltage loop runs through the connectors and covers of the charging path – inlet, charger and their HV leads – and breaks as soon as one of them is unplugged, so the module can keep that path de-energised. It is separate from the interlock of battery and drive, which uses P0A0A ff. Volvo stores P0D1513 in the on-board charger of the 2021–2023 XC40 Recharge when AC charging fails; bulletin TJ 36522 blames catches on the AC HV connector between inlet and charger that were not fully closed at the plant and has the connector reseated and latched. GM's Volt and ELR monitor such a charging loop with a 5 V source, and a Ford patent describes interlock shorting bars in connectors. Other loop faults are P0D16–P0D19.
Possible causes
- HV connector in the charging path not fully seated or latched (Volvo XC40)
- Broken interlock wire or pushed-back terminal
- Missing or loose cover on a charging component
Possible symptoms
- AC charging not possible
- Charge inlet light indicates a fault
Diagnosis
Use a compatible scan tool to confirm the code and check related codes and live data. Inspect the relevant wiring, connectors, power, ground and sensor signals using the vehicle manufacturer’s wiring diagram and service specifications. Do not replace a component based on the code alone.
Related DTC codes
Search this code in DTC Search
Generic OBD-II reference only. Manufacturer-specific definitions, test values and repair procedures can vary by vehicle. Verify with vehicle-specific service information.