P0A0C – High Voltage System Interlock Circuit A Low
The voltage sensed on interlock loop A is too low while the module drives the loop – typically an opened loop or a short to ground. GM documents it codegenau: in its 2016 HPC2 table P0A0C sets when the sensed interlock voltage stays below 30 % of the 5 V test signal in 2 of 2 samples (12.5 ms each) with the 12 V supply above 10.2 V; it is Type A, so the MIL lights after one trip. The 2011 Volt tables used a 10 % threshold. Mercedes-Benz model line 243 stores P0A0C00 in the DC converter and on-board charger as a short to ground in the interlock circuit. The opposite fault is P0A0D. Since the loop guards against live HV parts, the system drops the contactors and the car will not drive on electric power.
Possible causes
- HV connector, cover or service disconnect open, interrupting the loop
- Interlock wire shorted to ground, e.g. chafed at a module or the body
- Corroded or pushed-back interlock pins
- Faulty interlock source or sense stage in the battery or hybrid module
Possible symptoms
- Check engine light (GM Type A) and hybrid/EV warning
- No ready mode, electric drive unavailable
- Charging may be blocked
Diagnosis
Use a compatible scan tool to confirm the code and check related codes and live data. Inspect the relevant wiring, connectors, power, ground and sensor signals using the vehicle manufacturer’s wiring diagram and service specifications. Do not replace a component based on the code alone.
Related DTC codes
Search this code in DTC Search
Generic OBD-II reference only. Manufacturer-specific definitions, test values and repair procedures can vary by vehicle. Verify with vehicle-specific service information.