P0D16 – Battery Charging System A High Voltage Interlock Circuit Performance
P0D16 flags a charging interlock loop that delivers a signal, just not the one expected – for example a reading that fails to follow when the module switches its test source on and off. No manufacturer documents P0D16 publicly. GM's Chevrolet Volt and Cadillac ELR show how such a loop is checked: the module feeds 5 V into the charging HVIL and compares the sensed level, as a share of the reference, against limits with the source on and off, which leads to P0D17 or P0D18. A Ford patent explains interlock loops built from shorting bars in connectors. Contact resistance in a connector, a plug inserted only partway and corrosion are typical. Open loops are P0D15, sporadic faults P0D19, the drive-side counterpart P0A0B. Charging is usually blocked.
Possible causes
- Contact resistance or corrosion in an interlock connector
- HV connector in the charging path inserted only partway
- Fault in the module's interlock source or measuring stage
Possible symptoms
- Charging refused
- Charging system warning
Diagnosis
Use a compatible scan tool to confirm the code and check related codes and live data. Inspect the relevant wiring, connectors, power, ground and sensor signals using the vehicle manufacturer’s wiring diagram and service specifications. Do not replace a component based on the code alone.
Related DTC codes
Search this code in DTC Search
Generic OBD-II reference only. Manufacturer-specific definitions, test values and repair procedures can vary by vehicle. Verify with vehicle-specific service information.