P0D54 – Battery Charger Hybrid/EV Battery Output Current Sensor Circuit High
P0D54 marks a current reading at the charger's high-voltage output that exceeds the sensor's upper limit. The limit sits well above normal charging current, so the value counts as an electrical fault rather than real current. GM's 2011 Volt charger module triggers at 18 A or more, the 2014 Volt/ELR table at 17.7 A, each over 400 of 500 ms and rated Type A with MIL. Mitsubishi's 2022 Outlander PHEV logs it as a short to supply once the sensor voltage exceeds 4.658 V, corresponding to roughly 54 A, for 0.5 s; charging is stopped and the charger/DC-DC unit replaced. While P0D54 is stored, GM suspends its output power plausibility test P0D5C. The low-side fault is P0D53.
Possible causes
- Current sensor output shorted to supply voltage in the charger
- Charger current measuring stage failed
- Sensor output stuck at its upper end
Possible symptoms
- AC charging interrupted or refused
- MIL on (GM)
- Charge level stays unchanged after plugging in
Diagnosis
Use a compatible scan tool to confirm the code and check related codes and live data. Inspect the relevant wiring, connectors, power, ground and sensor signals using the vehicle manufacturer’s wiring diagram and service specifications. Do not replace a component based on the code alone.
Related DTC codes
Search this code in DTC Search
Generic OBD-II reference only. Manufacturer-specific definitions, test values and repair procedures can vary by vehicle. Verify with vehicle-specific service information.