P0D51 – Battery Charger Hybrid/EV Battery Output Current Sensor Circuit

P0D51 covers a circuit fault of the sensor that measures the direct current the on-board charger pushes into the traction battery. No manufacturer documents P0D51 itself. GM's charger module for the Volt and ELR and Mitsubishi's Outlander PHEV use the low and high codes P0D53 and P0D54 for electrical faults of this sensor, and Mitsubishi adds P0D52 for an offset check. Without a usable current value the charger can neither regulate charging current nor prove that its output power matches its input, a check GM performs under P0D5C. CARB obliges plug-in hybrids to detect charger malfunctions that prevent or slow charging. Expect AC charging to be blocked while the vehicle itself keeps driving.

Possible causes

Possible symptoms

Diagnosis

Use a compatible scan tool to confirm the code and check related codes and live data. Inspect the relevant wiring, connectors, power, ground and sensor signals using the vehicle manufacturer’s wiring diagram and service specifications. Do not replace a component based on the code alone.

Related DTC codes

Search this code in DTC Search

Generic OBD-II reference only. Manufacturer-specific definitions, test values and repair procedures can vary by vehicle. Verify with vehicle-specific service information.