P0D4F – Battery Charger Hybrid/EV Battery Output Voltage Sensor Circuit High
P0D4F is the high-side fault of the charger's output voltage sensor: the reading climbs beyond anything the battery could actually present. GM's 2011-2014 charger module for the Volt and ELR flags a decoded value of 482 V or more for 400 of 500 ms as a Type A fault with immediate MIL. In the 2016-2019 Volt the sensor delivers a pulse-width signal; 92 % duty cycle or more, or a line resting at 0 %, counts as high and is rated Type B. For the 2022 Outlander PHEV Mitsubishi sets the code at a sensor voltage above 3.5 V, about 632 V, held for 0.5 s, describes it as a short to supply, stops charging and replaces the charger/DC-DC unit. GM's Bolt EI PIE0828 names it too. The low counterpart is P0D4E.
Possible causes
- Voltage sensor signal shorted to a supply voltage inside the charger
- Measuring stage of the on-board charger failed
- Charger software misinterprets the signal
Possible symptoms
- AC charging refused
- MIL on (GM)
- Charging interrupted with fault message
Diagnosis
Use a compatible scan tool to confirm the code and check related codes and live data. Inspect the relevant wiring, connectors, power, ground and sensor signals using the vehicle manufacturer’s wiring diagram and service specifications. Do not replace a component based on the code alone.
Related DTC codes
Search this code in DTC Search
Generic OBD-II reference only. Manufacturer-specific definitions, test values and repair procedures can vary by vehicle. Verify with vehicle-specific service information.