P0D4E – Battery Charger Hybrid/EV Battery Output Voltage Sensor Circuit Low
P0D4E reports a signal below the valid range for the sensor measuring the charger's DC output toward the traction battery. In GM's charger module for the 2011-2014 Volt and ELR the raw value must stay at or below 2.62 V for 400 of 500 ms; the fault is Type A and lights the MIL at once. The 2016-2019 Volt reads the sensor as a duty cycle and treats 8 % or less, or a signal stuck at 100 %, as low, Type B. Mitsubishi's 2022 Outlander PHEV calls it a short to ground: under 0.943 V, equal to about -7 V, for 0.5 s; charging is stopped and the charger/DC-DC unit is replaced. GM's Bolt EI PIE0828 also lists the code. Its counterpart is P0D4F; plausibility errors fall under P0D4D.
Possible causes
- Voltage sensor signal shorted to ground inside the charger
- On-board charger (Mitsubishi charger/DC-DC unit) failed
- Internal reference supply of the measuring circuit missing
Possible symptoms
- Charging stops or does not start
- MIL on (GM)
- Charging fault message
Diagnosis
Use a compatible scan tool to confirm the code and check related codes and live data. Inspect the relevant wiring, connectors, power, ground and sensor signals using the vehicle manufacturer’s wiring diagram and service specifications. Do not replace a component based on the code alone.
Related DTC codes
Search this code in DTC Search
Generic OBD-II reference only. Manufacturer-specific definitions, test values and repair procedures can vary by vehicle. Verify with vehicle-specific service information.