P0C78 – Hybrid/EV Battery System Precharge Time Too Long
P0C78 means precharge took too long: the inverter side did not come up to battery voltage within the allowed time. GM's 2011 Volt allows 700 ms to reach 95 % (Type A), the 2013 eAssist 1,000 ms or more than 5 A for over 100 ms (Type B), and the 2019 tables demand 95-105 % at 0.700 s, Type A. The 2018 Outlander PHEV flags a gap of 12 V or more between battery and inverter after 1 s. Typical causes are an open precharge resistor or fuse, a high-voltage load pulling the bus down, and software. Bulletins cover a blown fuse in the service disconnect (Bolt EV, 18-NA-225), a failed coolant heater (Spark EV, 16-NA-072) and battery-module software at Chrysler and Volvo. The vehicle then normally will not become ready.
Possible causes
- Precharge resistor, precharge contactor or high-voltage fuse open
- Faulty high-voltage consumer such as a coolant heater loading the bus
- Battery module software, fixed by an update
- Loose high-voltage cable or bus bar
Possible symptoms
- Vehicle does not become ready to drive
- Malfunction indicator lamp and drive system message
- Loss of propulsion
Diagnosis
Use a compatible scan tool to confirm the code and check related codes and live data. Inspect the relevant wiring, connectors, power, ground and sensor signals using the vehicle manufacturer’s wiring diagram and service specifications. Do not replace a component based on the code alone.
Related DTC codes
Search this code in DTC Search
Generic OBD-II reference only. Manufacturer-specific definitions, test values and repair procedures can vary by vehicle. Verify with vehicle-specific service information.