P0D26 – Battery Charger System Precharge Time Too Long

P0D26 means the charger's high-voltage bus did not come up to battery voltage within the allowed precharge time. GM's Volt 2011 to 2015 and ELR 2014 to 2016 require the bus to sit within 5 % of pack voltage for 0.25 s before 10 s have passed; the 2016 and 2017 Volt allow only 0.700 s to reach 95 % (later 95 to 105 %); all are One Trip Type A. Mitsubishi's Outlander PHEV looks at the charger's own capacitor, which must charge to 120 or 240 V within 45 s, otherwise charging stops. Bulletin PIP4905E links P0D26 on the Volt and ELR to no charging and asks for HPCM2 software, then a check of the proximity signal and charge port for water or corrosion; on the Bolt EV (18-NA-225) it comes with P0C78 when the fuse in the manual disconnect has opened. The main battery precharge is P0C78.

Possible causes

Possible symptoms

Diagnosis

Use a compatible scan tool to confirm the code and check related codes and live data. Inspect the relevant wiring, connectors, power, ground and sensor signals using the vehicle manufacturer’s wiring diagram and service specifications. Do not replace a component based on the code alone.

Related DTC codes

Search this code in DTC Search

Generic OBD-II reference only. Manufacturer-specific definitions, test values and repair procedures can vary by vehicle. Verify with vehicle-specific service information.