P0C77 – Hybrid/EV Battery System Precharge Time Too Short

P0C77 is stored when the inverter side reaches battery voltage too quickly during precharge. Before the main contactor closes, the controller charges the inverter capacitor through a precharge resistor and watches the ratio of bus to battery voltage. GM's 2011 Volt sets the code if that ratio passes 95 % within 50 ms of precharge start, Type A; the 2013 eAssist uses 75 ms, Type B, and both require the bus to be below 40 V beforehand. A rise that fast suggests a bypassed or shorted resistor, a main contactor that is welded or closes early, or far less capacitance on the bus than expected. Chrysler lists P0C77 for the 2017 Pacifica Hybrid together with a high-voltage cable that had worked loose on the inverter terminal (08-107-17). Propulsion may be unavailable.

Possible causes

Possible symptoms

Diagnosis

Use a compatible scan tool to confirm the code and check related codes and live data. Inspect the relevant wiring, connectors, power, ground and sensor signals using the vehicle manufacturer’s wiring diagram and service specifications. Do not replace a component based on the code alone.

Related DTC codes

Search this code in DTC Search

Generic OBD-II reference only. Manufacturer-specific definitions, test values and repair procedures can vary by vehicle. Verify with vehicle-specific service information.