P0BB0 – Hybrid/EV Battery Voltage Sense X Circuit Low
When channel X reads too low, P0BB0 is stored. In GM's eAssist mild hybrid the battery interface module sets it below 1.4 V in seven of ten samples at 200 ms, provided the 12 V system is above 8.8 V and the group fault P1B38 is not active, as a two-trip Type B fault. The 2011 Volt and the 16OBDG02 programme work with a far lower limit of about 0.2 V, the latter in 14 of 18 samples at 100 ms, Type A. That difference reflects the cell chemistry and how much voltage a healthy cell can lose. Because an open lead is caught first by P0BAE, a stand-alone P0BB0 is more often a short in the sense harness, a failed input or a cell that has collapsed. Expect reduced power and blocked charging.
Possible causes
- Short between sense lead X and a lower potential
- Defective measuring channel X in the monitoring electronics
- Cell X collapsed or internally shorted
Possible symptoms
- Hybrid system warning and MIL
- Electric assist or propulsion reduced
- Charging not possible
Diagnosis
Use a compatible scan tool to confirm the code and check related codes and live data. Inspect the relevant wiring, connectors, power, ground and sensor signals using the vehicle manufacturer’s wiring diagram and service specifications. Do not replace a component based on the code alone.
Related DTC codes
Search this code in DTC Search
Generic OBD-II reference only. Manufacturer-specific definitions, test values and repair procedures can vary by vehicle. Verify with vehicle-specific service information.