P0BAB – Hybrid/EV Battery Voltage Sense W Circuit Low
A W channel reading at or near zero sets P0BAB. How low is too low depends on the battery: GM's lithium-ion modules of 2016 and 2019 react to 0.2 V or less held for 1.4 s within a 2 s window, Type A, and the 16OBDG02 programme to under 0.20 V in 14 of 18 samples at 100 ms. The eAssist mild hybrid already fails below 1.4 V, seven of ten samples, as long as the 12 V supply exceeds 8.8 V and P1B38 is not active; that fault is Type B. All of these tests stand down while an open sense line fault is present, so a simply broken lead shows up as P0BA9. P0BAB on its own suggests a short towards a lower potential, a dead measuring input or a deeply discharged cell. Power and charging are usually restricted.
Possible causes
- Sense lead W shorted to a lower cell potential
- Measuring input for W on the monitoring board failed
- Cell W deeply discharged or internally shorted
Possible symptoms
- Hybrid or EV warning and MIL
- Reduced power output
- Charging limited or blocked
Diagnosis
Use a compatible scan tool to confirm the code and check related codes and live data. Inspect the relevant wiring, connectors, power, ground and sensor signals using the vehicle manufacturer’s wiring diagram and service specifications. Do not replace a component based on the code alone.
Related DTC codes
Search this code in DTC Search
Generic OBD-II reference only. Manufacturer-specific definitions, test values and repair procedures can vary by vehicle. Verify with vehicle-specific service information.