P0BAF – Hybrid/EV Battery Voltage Sense X Circuit Range/Performance

P0BAF covers a sense X signal that is electrically present yet does not behave like a real cell. For model year 2016 GM documents two versions in the same booklet. The Volt controller fails it when X moves in a different direction from the pack average, or by less than 0.005 V while that average moves more than 0.022 V, for 7 s within 8 s, Type A. The ELR variant samples every 200 ms, needs average movement above 0.006 V and fails after 20 of 40 samples, one trip. The eAssist hybrid asks for at least half of the average change, Type B over two trips, and GM's 2019 processor uses a 0.005 V trend test. Since the check pauses during circuit, low or high faults, P0BAF points to a stuck measurement rather than a broken wire.

Possible causes

Possible symptoms

Diagnosis

Use a compatible scan tool to confirm the code and check related codes and live data. Inspect the relevant wiring, connectors, power, ground and sensor signals using the vehicle manufacturer’s wiring diagram and service specifications. Do not replace a component based on the code alone.