P0B15 – Hybrid/EV Battery Pack Voltage Sense B Circuit Range/Performance
P0B15 marks pack voltage measurement B as electrically valid but implausible: the value lies within the sensor range yet does not match a reference, typically the sum of the cell voltages or another pack measurement. No manufacturer documents this code publicly. GM shows the principle on channel A: P0ABB fails when pack voltage and summed cell voltages differ by more than 12 V, 20 of 25 samples at 25 ms, Type A, one trip. CARB demands rationality checks for battery voltage sensors of the hybrid storage system. Hard circuit faults of channel B are P0B14, P0B16 and P0B17. Because state of charge and cell protection rely on this value, the controller restricts power or charging.
Possible causes
- Drift or calibration error of measurement channel B
- Faulty cell voltage acquisition distorts the reference sum
- Increased contact resistance at sense terminals
- Battery controller software needs an update
Possible symptoms
- MIL and hybrid/EV system warning on
- Battery power limited, reduced electric drive or assist
- Implausible state-of-charge or range display
Diagnosis
Use a compatible scan tool to confirm the code and check related codes and live data. Inspect the relevant wiring, connectors, power, ground and sensor signals using the vehicle manufacturer’s wiring diagram and service specifications. Do not replace a component based on the code alone.
Related DTC codes
Search this code in DTC Search
Generic OBD-II reference only. Manufacturer-specific definitions, test values and repair procedures can vary by vehicle. Verify with vehicle-specific service information.