P0ABB – Hybrid/EV Battery Pack Voltage Sense A Circuit Range/Performance
P0ABB is a plausibility check: the measured pack voltage is within electrical limits but does not agree with what the individual cells add up to. GM documents it in several hybrid tables. From 2016 the battery controller flags it when pack voltage and the sum of cell voltages differ by more than 10 V in 32 of 40 samples; the 2013 table compares the pack reading with 32 times the average cell voltage and uses a 5.49 V limit. Both are Type B, so the MIL needs two trips. The check is suppressed while cell voltage circuit faults are active. P0ABC and P0ABD cover hard low or high readings, P0AF8 compares the pack sensor with the inverter bus voltage.
Possible causes
- Pack voltage measurement drifted (divider or input aging)
- Faulty cell voltage tap distorting the cell sum
- High-resistance busbar or sense connection
Possible symptoms
- Check engine or hybrid system warning light
- Erratic state-of-charge display
- Reduced electric power
Diagnosis
Use a compatible scan tool to confirm the code and check related codes and live data. Inspect the relevant wiring, connectors, power, ground and sensor signals using the vehicle manufacturer’s wiring diagram and service specifications. Do not replace a component based on the code alone.
Related DTC codes
Search this code in DTC Search
Generic OBD-II reference only. Manufacturer-specific definitions, test values and repair procedures can vary by vehicle. Verify with vehicle-specific service information.