P0B16 – Hybrid/EV Battery Pack Voltage Sense B Circuit Low

P0B16 sets when pack voltage measurement B reports a value below its plausible minimum, usually an electrical cause such as a sense lead shorted to ground or an open input that pulls the reading down. No manufacturer documents this code publicly. GM uses the same logic on channel A: on its BECM P0ABC sets when the pack-side voltage drops below 24 V for 1.6 s within a 2 s window, Type A, one trip. CARB requires out-of-range monitoring of battery voltage sensors in hybrid storage systems. The opposite fault is P0B17, implausible but in-range values are P0B15. Without a trustworthy pack voltage the controller may refuse to close the contactors or limit operation.

Possible causes

Possible symptoms

Diagnosis

Use a compatible scan tool to confirm the code and check related codes and live data. Inspect the relevant wiring, connectors, power, ground and sensor signals using the vehicle manufacturer’s wiring diagram and service specifications. Do not replace a component based on the code alone.

Related DTC codes

Search this code in DTC Search

Generic OBD-II reference only. Manufacturer-specific definitions, test values and repair procedures can vary by vehicle. Verify with vehicle-specific service information.