P0AA2 – Hybrid/EV Battery Positive Contactor Circuit Stuck Open

P0AA2 means the positive main contactor does not close, or does not conduct, when the controller commands it closed, so the high-voltage bus cannot be energised from the pack. Audi documents it for the 2020-2022 Q5 e quattro and 2021-2022 A7 e quattro plug-in hybrids: the car does not start and the battery management module stores P0AA2 (often with P0AA5). Audi traces rare cases to oxidised contact surfaces in the battery junction box after long standing or high humidity, and first prescribes repeated ignition cycles and an EV road test before replacing the junction box. GM lists the code among high-voltage faults for which Ultium EV pack data must be collected. Unlike P0AA1, the contacts are open, not welded.

Possible causes

Possible symptoms

Diagnosis

Use a compatible scan tool to confirm the code and check related codes and live data. Inspect the relevant wiring, connectors, power, ground and sensor signals using the vehicle manufacturer’s wiring diagram and service specifications. Do not replace a component based on the code alone.

Related DTC codes

Search this code in DTC Search

Generic OBD-II reference only. Manufacturer-specific definitions, test values and repair procedures can vary by vehicle. Verify with vehicle-specific service information.