P0AA5 – Hybrid/EV Battery Negative Contactor Circuit Stuck Open
P0AA5 is set when the negative main contactor stays open or fails to conduct after the controller has commanded it closed, so the negative side of the high-voltage bus never connects. Audi reports it, alone or with P0AA2, on the 2020-2022 Q5 e quattro and 2021-2022 A7 e quattro plug-in hybrids with a no-start complaint; the stated cause is oxidation of the contact surfaces in the battery junction box after very long standing or extreme humidity. Audi's procedure: several ignition cycles and an EV road test with many consumers on, and a new junction box only if the fault returns. GM includes P0AA5 among the Ultium EV high-voltage codes that require pack data retrieval. It is the counterpart of P0AA4 (welded contacts).
Possible causes
- Oxidised contact surfaces after long standing or high humidity (Audi)
- Failed battery junction box or burnt negative contactor
- Contactor coil not energised due to wiring or 12 V supply fault
Possible symptoms
- Vehicle does not start or reach ready mode
- Hybrid or high voltage battery warning
- Charging not possible
Diagnosis
Use a compatible scan tool to confirm the code and check related codes and live data. Inspect the relevant wiring, connectors, power, ground and sensor signals using the vehicle manufacturer’s wiring diagram and service specifications. Do not replace a component based on the code alone.
Related DTC codes
Search this code in DTC Search
Generic OBD-II reference only. Manufacturer-specific definitions, test values and repair procedures can vary by vehicle. Verify with vehicle-specific service information.