P0AA1 – Hybrid/EV Battery Positive Contactor Circuit Stuck Closed
P0AA1 means the positive main contactor conducts although it should be open, typically because its contacts have welded. GM checks this with all contactors commanded open for over 120 s (or the bus already below 9 % of pack voltage): more than 30 V on the positive bus in 4 of 6 samples sets Type B (two trips, 19OBDG02). Older GM programs test during precharge instead and set Type A after one trip if bus voltage exceeds 80 % (2011) or 60 % (2016) of pack voltage. GM bulletins cover the 2017 Bolt EV and welded contactors on the 2019 Volt; Jeep fixes false sets on the 2023 Grand Cherokee 4xe with software, Mitsubishi lists it as main contactor (+) seizure on the i-MiEV. The car may refuse to start.
Possible causes
- Positive contactor contacts welded, e.g. after high current or arcing
- Battery or hybrid controller software (GM Volt 2019, Jeep 4xe updates)
- Faulty battery disconnect unit (GM Bolt EV bulletin)
- Bus voltage sensing error making an open contactor look closed
Possible symptoms
- Vehicle will not switch into ready or propulsion-active mode
- Check engine light and service high voltage system message
- Often stored together with P0AA4 or a slow discharge code such as P0C76
Diagnosis
Use a compatible scan tool to confirm the code and check related codes and live data. Inspect the relevant wiring, connectors, power, ground and sensor signals using the vehicle manufacturer’s wiring diagram and service specifications. Do not replace a component based on the code alone.
Related DTC codes
Search this code in DTC Search
Generic OBD-II reference only. Manufacturer-specific definitions, test values and repair procedures can vary by vehicle. Verify with vehicle-specific service information.