P2E3D – Battery Charger B Output Shorted
P2E3D points to a short on the high-voltage output side of charger B. No manufacturer documents P2E3D publicly. GM's test for the A-side code P0D23 shows how such a short is found: while the charger contactor is only precharging and the multi-purpose contactor is open, hardly any current should flow, so more than 0.35 A on the charger bus in 4 of 5 samples at 100 ms sets the code as One Trip Type A, both in the 2011 Volt and in the 2016 Cadillac ELR tables. The test is suspended while output current sensor faults are active. Supplier chargers such as Holley's 30-8405 build in output short-circuit protection that shuts the stage down. Causes are an internal short in charger B, a damaged HV cable or a contactor path that leaks. Charging is blocked; current deviations alone are P2E3C.
Possible causes
- Internal short in the charger B output stage
- Damaged high-voltage cable between charger B and battery
- Leaking or stuck contactor path in the charging circuit
Possible symptoms
- Charging blocked as soon as the cable is plugged in
- High-voltage or charging system warning
Diagnosis
Use a compatible scan tool to confirm the code and check related codes and live data. Inspect the relevant wiring, connectors, power, ground and sensor signals using the vehicle manufacturer’s wiring diagram and service specifications. Do not replace a component based on the code alone.
Related DTC codes
Search this code in DTC Search
Generic OBD-II reference only. Manufacturer-specific definitions, test values and repair procedures can vary by vehicle. Verify with vehicle-specific service information.