P2E3B – Battery Charger B Output Voltage Too Low
P2E3B is set when the high-voltage output of charger B stays below what the control unit expects while charging. No manufacturer documents P2E3B publicly. For the A-side code P0D21, GM's 2016 tables for the Cadillac ELR use a fixed floor: in constant-current as well as constant-voltage mode the charger bus must not drop under 150 V, and 8 failures in 10 samples set the code as Type B. Stellantis stores P0D21-00 in the integrated dual charging module (IDCM) with the MIL on and the car refusing to charge, on the 2021 Wrangler 4xe (TSB 08-260-26, some cars also tripping the house circuit breaker) and the 2022 Pacifica plug-in hybrid (TSB 08-334-26); the fix in both is IDCM software. CARB requires such charger faults to be caught. Imprecise output is P2E3A, a short P2E3D.
Possible causes
- Charger module software fault fixed by reprogramming
- Failed power stage inside charger B
- High resistance in the HV output connection
Possible symptoms
- MIL on and vehicle will not charge
- Level 2 charging fails, wall box breaker may trip
Diagnosis
Use a compatible scan tool to confirm the code and check related codes and live data. Inspect the relevant wiring, connectors, power, ground and sensor signals using the vehicle manufacturer’s wiring diagram and service specifications. Do not replace a component based on the code alone.
Related DTC codes
Search this code in DTC Search