P2D84 – Battery Charger B Input Current Sensor Circuit High
P2D84 is the high-side fault of charger B's input current sensor: its signal climbs above what the measuring range allows. No manufacturer documents P2D84 publicly, so the A-side code P0D3B serves as reference. For the 2022 Outlander PHEV, Mitsubishi counts half a second of sensor output above 4.658 V (around +54 A) as a supply-side short and halts charging. GM's Volt module of 2011 sets its Type A fault once more than 24.78 A of AC is reported in 160 out of 200 ms. Real currents of that size would exceed what the charger draws by design, so the fault almost always lies in the measuring chain. P2D84 differs from P0E89, where the current is judged too high, not the sensor. Low counterpart: P2D83.
Possible causes
- Charger B current sensor output shorted toward its supply inside the unit
- Current sensor of charger B failed (charger repair or replacement)
- Reference or ground of the sensor lost, pushing the signal up
Possible symptoms
- AC charging does not start or stops within seconds
- Charging fault warning in the cluster
Diagnosis
Use a compatible scan tool to confirm the code and check related codes and live data. Inspect the relevant wiring, connectors, power, ground and sensor signals using the vehicle manufacturer’s wiring diagram and service specifications. Do not replace a component based on the code alone.
Related DTC codes
Search this code in DTC Search