P2D83 – Battery Charger B Input Current Sensor Circuit Low

P2D83 says the current sensor at the input of charger B outputs a signal under its valid range. No manufacturer documents P2D83 publicly. For charger A the same fault is P0D3A, which Mitsubishi interprets on the 2022 Outlander PHEV as a ground short. Below 0.344 V of sensor output (roughly -54 A) for half a second, with 10-16 V on the charger, ends the charge, and the repair is a replacement charger/DC-DC assembly. In GM's 2011 Volt, the charger module treats an AC reading below 0.8 A in 160 out of 200 ms as Type A. Toyota's RAV4 Prime proves that a B stage has its own input current monitoring. The sensor usually sits inside the charger. Too high is P2D84, implausible values P2D85, the general circuit code P0E8A.

Possible causes

Possible symptoms

Diagnosis

Use a compatible scan tool to confirm the code and check related codes and live data. Inspect the relevant wiring, connectors, power, ground and sensor signals using the vehicle manufacturer’s wiring diagram and service specifications. Do not replace a component based on the code alone.

Related DTC codes

Search this code in DTC Search

Generic OBD-II reference only. Manufacturer-specific definitions, test values and repair procedures can vary by vehicle. Verify with vehicle-specific service information.