P2A07 – O2 Sensor Negative Voltage Bank 1 Sensor 2
Sensor 2 on bank 1 is the switching oxygen sensor behind the converter; P2A07 says its output has dropped below zero volts. Because the voltage comes from the oxygen difference across the zirconia element, a negative value points to reversed signal and return wires, a contaminated reference air path or a cracked element. No manufacturer documents P2A07 publicly. The closest documented test is Ford's: from 2011 a rear sensor held below −0.2 V for 10 s, put down to swapped wires or sensor degradation – Ford, however, files it as P2A01. A Denso patent watches for a negative output in overrun shut-off, a phase in which the exhaust behind the converter is almost pure air, to find element cracks. As long as the signal is negative, the converter cannot be assessed and the downstream trim switches off.
Possible causes
- Signal and return wires swapped, e.g. after fitting a universal sensor
- Cracked sensing element
- Sensor degraded or reference air contaminated
Possible symptoms
- Check engine light on
- Catalyst monitor of bank 1 not ready
- Usually no noticeable change while driving
Diagnosis
Use a compatible scan tool to confirm the code and check related codes and live data. Inspect the relevant wiring, connectors, power, ground and sensor signals using the vehicle manufacturer’s wiring diagram and service specifications. Do not replace a component based on the code alone.
Related DTC codes
Search this code in DTC Search
Generic OBD-II reference only. Manufacturer-specific definitions, test values and repair procedures can vary by vehicle. Verify with vehicle-specific service information.