P0137 – O2 Sensor Circuit Low Voltage Bank 1 Sensor 2

The oxygen sensor after the catalytic converter on bank 1 (sensor 2) is a switching sensor (about 0.1–0.9 V) used for converter monitoring and fine mixture trim. P0137 means the signal stays below the lower limit. Documented limits: GM below 40–60 mV (two trips); Ford switches in a pull-up and reads open above 1 MΩ (20 kΩ from 2020) or short to ground below 10 Ω, within 10 s. Subaru uses the code as a functional test instead: the sensor never reaches 550 mV within 200 s after fuel cut-off, i.e. it behaves as if permanently lean – so a real exhaust leak can also trigger it there. When it fails, the control module stops the downstream trim and cannot evaluate the converter; there is no limp mode.

Possible causes

Possible symptoms

Diagnosis

Use a compatible scan tool to confirm the code and check related codes and live data. Inspect the relevant wiring, connectors, power, ground and sensor signals using the vehicle manufacturer’s wiring diagram and service specifications. Do not replace a component based on the code alone.

Related DTC codes

Search this code in DTC Search

Generic OBD-II reference only. Manufacturer-specific definitions, test values and repair procedures can vary by vehicle. Verify with vehicle-specific service information.