P0E8F – Drive Motor A Inverter Voltage Sensor B Circuit High
P0E8F is the upper-limit fault of inverter voltage sensor B on drive motor A. Mitsubishi's 2023 Outlander PHEV sets it when the main channel at capacitor 2 (V2M) reports at least 4.75 V for 0.16 s, again with the unit supplied at 8 V or above, and lists it as a range check maximum. A reading pinned at the top usually comes from the signal touching the sensor supply, from a lost sensor ground or from a defect in the measuring circuit. A real overvoltage of the bus cannot be ruled out, but it has its own code, P0C79, and would normally show on several channels at once; if sensor A (P0D30) and the battery voltage are normal, the B channel itself is suspect. P0E8E is the low counterpart. The controller protects the inverter by limiting or stopping electric drive.
Possible causes
- Measuring circuit for capacitor 2 inside the power drive unit defective
- Signal shorted to sensor supply or lost sensor ground
- Actual overvoltage on the high-voltage bus
Possible symptoms
- MIL and hybrid system warning
- Electric drive switched off or strongly reduced
Diagnosis
Use a compatible scan tool to confirm the code and check related codes and live data. Inspect the relevant wiring, connectors, power, ground and sensor signals using the vehicle manufacturer’s wiring diagram and service specifications. Do not replace a component based on the code alone.
Related DTC codes
Search this code in DTC Search
Generic OBD-II reference only. Manufacturer-specific definitions, test values and repair procedures can vary by vehicle. Verify with vehicle-specific service information.