P0E8E – Drive Motor A Inverter Voltage Sensor B Circuit Low

P0E8E means the output of inverter voltage sensor B for drive motor A has fallen to the bottom end of its scale. On the 2023 Outlander PHEV Mitsubishi assigns it to the main measuring channel of capacitor 2 (V2M) in the power drive unit and sets it when that signal stays at no more than 0.45 V for 0.16 s, provided the unit has at least 8 V supply; monitoring runs continuously. Electrically this matches a short to ground, a broken signal path or a sensing circuit that has died, because the high-voltage bus itself would rarely read near zero while the system is active. The same channel reading high is P0E8F, while capacitor 1 on sensor A uses P0D2F for its low case. As the controller cannot trust the bus voltage, electric drive is limited or switched off and the MIL comes on.

Possible causes

Possible symptoms

Diagnosis

Use a compatible scan tool to confirm the code and check related codes and live data. Inspect the relevant wiring, connectors, power, ground and sensor signals using the vehicle manufacturer’s wiring diagram and service specifications. Do not replace a component based on the code alone.

Related DTC codes

Search this code in DTC Search

Generic OBD-II reference only. Manufacturer-specific definitions, test values and repair procedures can vary by vehicle. Verify with vehicle-specific service information.