P0D5B – Battery Charger 14 Volt Output Power Performance
P0D5B checks whether the power leaving the charger's built-in 14 V output is physically possible. GM's charger module for the Volt and ELR multiplies the measured 14 V output voltage and current and compares the product with the AC input power times a factor of about 2 plus an offset: 2.5 W in the 2011 table, 125 W in the 2014 Volt/ELR and 2016 ELR tables. Exceeding that for 1.6 s within a 2 s window sets a Type A fault with MIL. The test only runs when the sensor codes P0D44, P0D45, P0D49 and P0D4A are clear, and the same low-voltage power also enters GM's total output check P1ECE. Because the 12 V side only takes part while charging, failures mostly show up as charging faults.
Possible causes
- Voltage or current measurement of the 14 V stage reads too high
- AC input power measured too low
- Low-voltage stage of the on-board charger faulty
Possible symptoms
- MIL on (GM)
- Charging interrupted
- 12 V battery not supported while plugged in
Diagnosis
Use a compatible scan tool to confirm the code and check related codes and live data. Inspect the relevant wiring, connectors, power, ground and sensor signals using the vehicle manufacturer’s wiring diagram and service specifications. Do not replace a component based on the code alone.
Related DTC codes
Search this code in DTC Search
Generic OBD-II reference only. Manufacturer-specific definitions, test values and repair procedures can vary by vehicle. Verify with vehicle-specific service information.