P0D4A – Battery Charger 14 Volt Output Current Sensor Circuit High
P0D4A sets when the current sensor in the charger's 14 V output reports 54 A or more. GM's battery charger control module in the 2011-2014 Volt and the ELR applies that threshold for 400 of 500 ms with the low-voltage section awake and treats the result as a Type A fault with MIL. Either the sensor signal is stuck high or the output is genuinely overloaded or shorted; GM's tables do not separate the two. P0D49 is the low counterpart, and both block GM's 14 V output power check P0D5B. Because the stage sits inside the on-board charger, the car's main DC/DC converter is not the place to look. Owners mainly notice that the car refuses to charge or stops charging soon after plugging in.
Possible causes
- Current sense signal stuck high inside the charger
- Overload or short on the charger's low-voltage output
- Failed on-board charger
Possible symptoms
- Vehicle will not charge
- MIL on (GM)
Diagnosis
Use a compatible scan tool to confirm the code and check related codes and live data. Inspect the relevant wiring, connectors, power, ground and sensor signals using the vehicle manufacturer’s wiring diagram and service specifications. Do not replace a component based on the code alone.
Related DTC codes
Search this code in DTC Search
Generic OBD-II reference only. Manufacturer-specific definitions, test values and repair procedures can vary by vehicle. Verify with vehicle-specific service information.