P0C16 – Drive Motor B Inverter Phase W Over Temperature

P0C16 is set by the motor B inverter when phase W runs too hot and the temperature sensor itself shows no fault. GM's tables give PIM sensor F above 98 °C for the 2011 Volt, above 88 °C with an 85 °C reset for the 2012 two-mode trucks, and 131 °C for 1.2 s within 2 s for the 2016 Volt, with 1.5 s in the 2019 table; each is Type A, one trip. Thermistor circuit codes such as P0BE0 and P0BE1 take priority and block the check. P0C14 and P0C15 are phases U and V, P0C13 is phase W on motor A. CARB allows some protective overtemperature strategies to run without MIL, but GM lights it here. Look for weak cooling first; until then motor B is derated.

Possible causes

Possible symptoms

Diagnosis

Use a compatible scan tool to confirm the code and check related codes and live data. Inspect the relevant wiring, connectors, power, ground and sensor signals using the vehicle manufacturer’s wiring diagram and service specifications. Do not replace a component based on the code alone.

Related DTC codes

Search this code in DTC Search

Generic OBD-II reference only. Manufacturer-specific definitions, test values and repair procedures can vary by vehicle. Verify with vehicle-specific service information.