P0C13 – Drive Motor A Inverter Phase W Over Temperature

P0C13 covers phase W of the motor A inverter: the controller sees a credible sensor reading that exceeds the overtemperature limit. GM's 2011 Volt uses PIM sensor E with 98 °C, the 2012 two-mode trucks 88 °C, the 2016 and 2018 tables 126 °C for 1.2 s within a 2 s window and the 2019 table 128 °C for 1.5 s, always Type A, one trip, so the MIL comes on at once. The check is blocked while circuit or performance faults of the thermistor are active. Siblings are P0C11 for phase U and P0C12 for phase V; P0C16 is phase W on motor B. Because the code reports a real heat condition, the cooling system of the power electronics is the first place to look; output stays limited.

Possible causes

Possible symptoms

Diagnosis

Use a compatible scan tool to confirm the code and check related codes and live data. Inspect the relevant wiring, connectors, power, ground and sensor signals using the vehicle manufacturer’s wiring diagram and service specifications. Do not replace a component based on the code alone.

Related DTC codes

Search this code in DTC Search

Generic OBD-II reference only. Manufacturer-specific definitions, test values and repair procedures can vary by vehicle. Verify with vehicle-specific service information.