P0C0E – Drive Motor B Inverter Power Supply Circuit/Open

P0C0E is the motor B counterpart of P0C0B: the inverter for the second motor has lost the supply of its gate-drive board. GM documents it on the Volt and the two-mode trucks. The IGBT module reports a bias fault through its status line when the supply of phase A, B or C fails. The 2011 Volt checks with high voltage above 100 V, the 2012 trucks with run/crank voltage between 9.5 and 18 V, both after one count, Type A. The 2016 Volt needs 0.002 s of fault in a 0.024 s window, the 2018 table 0.02 s, the 2019 table 0.168 s, always Type A, one trip. P0C0F and P0C10 cover low and high supply. Motor B can no longer be driven, so propulsion is reduced.

Possible causes

Possible symptoms

Diagnosis

Use a compatible scan tool to confirm the code and check related codes and live data. Inspect the relevant wiring, connectors, power, ground and sensor signals using the vehicle manufacturer’s wiring diagram and service specifications. Do not replace a component based on the code alone.

Related DTC codes

Search this code in DTC Search

Generic OBD-II reference only. Manufacturer-specific definitions, test values and repair procedures can vary by vehicle. Verify with vehicle-specific service information.