P0C0B – Drive Motor A Inverter Power Supply Circuit/Open

P0C0B flags a lost or interrupted supply inside the motor A inverter. GM reads it from the IGBT module status: when the gate drive supply falls below its threshold, the module reports a bias fault; on eAssist the 5 V rail below 3.5 to 4.3 V or the 15 V rail below 10.4 to 12.6 V counts, with run/crank above 7 V. The 2012 trucks enable it between 9.5 and 18 V; the 2016 to 2019 tables need 0.002 to 0.168 s of fault within short windows, Type A, one trip. Mercedes applies the code to the high-voltage supply of the inverter in the belt starter-alternator of P3 hybrids (subtypes 16 and 17) and replaces that unit. Expect loss of electric drive or engine start.

Possible causes

Possible symptoms

Diagnosis

Use a compatible scan tool to confirm the code and check related codes and live data. Inspect the relevant wiring, connectors, power, ground and sensor signals using the vehicle manufacturer’s wiring diagram and service specifications. Do not replace a component based on the code alone.

Related DTC codes

Search this code in DTC Search

Generic OBD-II reference only. Manufacturer-specific definitions, test values and repair procedures can vary by vehicle. Verify with vehicle-specific service information.