P0BF7 – Drive Motor B Phase V Current Sensor Circuit Low
P0BF7 reports that the phase V current sensor of the motor B inverter outputs a signal below its valid range. In GM's hybrid tables the converted current must fall below -800 A on the 2011 Volt (Type A, one trip), below -700 A on the 2012 and 2013 two-mode trucks (Type B, two trips, 10 of 15 samples) or below -700 A for 0.05 of 0.1 s (2016) and 0.1 of 0.15 s (2019), both Type A. Values like these are physically impossible for the motor phase, so the controller treats them as a sensor or circuit failure, for example a shorted output or a lost sensor supply. Unlike P0BF6 the sensor is not merely offset but outside its measuring range. Drive motor B then runs restricted.
Possible causes
- Failed phase V current sensor in the motor B inverter
- Sensor signal or supply pulled to ground on the sensor board
- Poor contact at an internal or external inverter connector
Possible symptoms
- Malfunction indicator lamp and hybrid warning
- Reduced power or no contribution from drive motor B
- Possible shutdown of electric drive
Diagnosis
Use a compatible scan tool to confirm the code and check related codes and live data. Inspect the relevant wiring, connectors, power, ground and sensor signals using the vehicle manufacturer’s wiring diagram and service specifications. Do not replace a component based on the code alone.
Related DTC codes
Search this code in DTC Search
Generic OBD-II reference only. Manufacturer-specific definitions, test values and repair procedures can vary by vehicle. Verify with vehicle-specific service information.