P0BEB – Drive Motor A Phase V Current Sensor Circuit Low
P0BEB reports that the phase V current sensor in the motor A inverter outputs a signal below its valid range. GM compares the converted current with a lower limit: below -700 A for 0.05 of 0.1 s (2016 tables) or 0.1 of 0.15 s (2019 table), Type A, one trip; below -800 A, Type A, on the 2011 Volt; below -700 A, Type B, two trips, on the 2012 two-mode trucks. Real phase currents never reach these values, so the code points to an electrical fault such as a sensor output pulled toward ground or a dead sensor. Unlike P0BEA, the sensor is not just shifted but out of its measuring range. Motor A is then run in a restricted mode.
Possible causes
- Failed phase V current sensor inside the inverter
- Sensor signal or supply pulled to ground on the sensor board
- Poor contact at an internal or external inverter connector
Possible symptoms
- Malfunction indicator lamp and hybrid warning
- Reduced power from drive motor A
- Possible shutdown of electric drive
Diagnosis
Use a compatible scan tool to confirm the code and check related codes and live data. Inspect the relevant wiring, connectors, power, ground and sensor signals using the vehicle manufacturer’s wiring diagram and service specifications. Do not replace a component based on the code alone.
Related DTC codes
Search this code in DTC Search
Generic OBD-II reference only. Manufacturer-specific definitions, test values and repair procedures can vary by vehicle. Verify with vehicle-specific service information.