P0A98 – Hybrid/EV Battery Pack Cooling Fan 2 Stuck On

P0A98 reports that battery cooling fan 2 keeps running after the controller has commanded it off; it mirrors P0A83 for fan 1. No manufacturer documents this code publicly. CARB calls for fan outputs to be checked for correct response to commands. GM's published method for fan 1 (sense code P0BC8) flags a fan that still reports more than about 250 rpm after being off for over 20 s; the same logic applies to a second fan. Typical causes are a welded relay, a control wire shorted to supply or fan electronics that ignore the stop command. Cooling is not at risk, but the fan can drain the 12 V battery and is audible after shutdown. Fan 2 circuit codes are P0A96, P0A99 and P0A9A.

Possible causes

Possible symptoms

Diagnosis

Use a compatible scan tool to confirm the code and check related codes and live data. Inspect the relevant wiring, connectors, power, ground and sensor signals using the vehicle manufacturer’s wiring diagram and service specifications. Do not replace a component based on the code alone.

Related DTC codes

Search this code in DTC Search

Generic OBD-II reference only. Manufacturer-specific definitions, test values and repair procedures can vary by vehicle. Verify with vehicle-specific service information.