P0BC1 – Hybrid/EV Battery Pack Cooling Fan Supply Voltage Circuit High

P0BC1 flags voltage on the battery fan feed when there should be none, or more than expected. GM documents it for the battery pack control module of its Two-Mode hybrid SUVs and pickups (Tahoe, Yukon, Escalade, Silverado, Sierra; 2012 and 2013 tables) as a welded fan relay: with the fan commanded off, a fan monitor voltage of at least 0.9 V in 10 of 20 samples at 100 ms sets it, provided the 12 V system is between 9 and 18 V and no fan circuit code (P0A81) is active. It is Type B, MIL after two trips. A stuck relay keeps the fan running with the vehicle off and drains the 12 V battery. The open and low cases are P0BBF and P0BC0; a fan that keeps turning without this fault is P0A83.

Possible causes

Possible symptoms

Diagnosis

Use a compatible scan tool to confirm the code and check related codes and live data. Inspect the relevant wiring, connectors, power, ground and sensor signals using the vehicle manufacturer’s wiring diagram and service specifications. Do not replace a component based on the code alone.

Related DTC codes

Search this code in DTC Search

Generic OBD-II reference only. Manufacturer-specific definitions, test values and repair procedures can vary by vehicle. Verify with vehicle-specific service information.