P049D – EGR A Control Position Exceeded Learning Limit
Exhaust gas recirculation (EGR) routes part of the exhaust back into the intake to lower combustion temperature and NOx. P049D checks the learned zero point – the fully closed position – of EGR valve A. The module learns the position sensor voltage with the valve closed, at GM during the after-run following ignition off; if the learned value lies outside a window (GM 2018: 83.5–93.5 % of 5 V, GM 2016: 16.4–25.1 %) or the values scatter too much (GM Duramax LML above 30 %), the code sets – MIL after two trips at GM, immediately after learning at Ford. Usually soot at the seat keeps the valve from closing, or a new valve was not taught in.
Possible causes
- Soot or deposits at the valve seat, valve does not close fully
- Position sensor A faulty or characteristic shifted
- New or cleaned valve not taught in, or wrong part
- Position sensor circuit fault as the primary cause
Possible symptoms
- Check engine light on
- Usually no driveability effect
- EGR possibly switched off, rough idle if the valve stays open
Diagnosis
Use a compatible scan tool to confirm the code and check related codes and live data. Inspect the relevant wiring, connectors, power, ground and sensor signals using the vehicle manufacturer’s wiring diagram and service specifications. Do not replace a component based on the code alone.
Related DTC codes
Search this code in DTC Search
Generic OBD-II reference only. Manufacturer-specific definitions, test values and repair procedures can vary by vehicle. Verify with vehicle-specific service information.