P042F – EGR A Control Stuck Closed

Exhaust gas recirculation (EGR) routes part of the exhaust back into the intake to lower combustion temperature and NOx. P042F means EGR valve A does not follow the opening command: its actual position stays more closed than commanded although the actuator works with high opening duty. GM's diesels of 2016/17 set it after about 1–8 s with MIL on the first trip; a GM bulletin covers it on the 2017 Cruze diesel. Ford petrol engines use position limits for 4 s; Ford diesels report both directions under P042E. With too little EGR, NOx rises, petrol engines may knock and P0401 can follow.

Possible causes

Possible symptoms

Diagnosis

Use a compatible scan tool to confirm the code and check related codes and live data. Inspect the relevant wiring, connectors, power, ground and sensor signals using the vehicle manufacturer’s wiring diagram and service specifications. Do not replace a component based on the code alone.

Related DTC codes

Search this code in DTC Search

Generic OBD-II reference only. Manufacturer-specific definitions, test values and repair procedures can vary by vehicle. Verify with vehicle-specific service information.