P0152 – O2 Sensor Circuit High Voltage Bank 2 Sensor 1

The oxygen sensor before the catalytic converter on bank 2 (sensor 1) is the main control sensor for the mixture. It is either a switching sensor (about 0.1 V lean to 0.9 V rich) or a wide-band sensor that works with a pump current evaluated by an interface chip. Bank 2 exists only on engines with two exhaust manifolds. P0152 is the bank 2 counterpart of P0132. Switching sensors: GM above 1050 mV (100 of 125 samples, after warm-up), Ford above 1.1 V for 10 s – a reading the sensor cannot produce itself, so heater or battery voltage on the signal wire is the usual cause; GM also reads an open wire as high. Wide-band sensors: a sensor wire shorted to voltage. P0152 together with P0158 points to a shared short in the bank 2 harness. Two trips. A stored code usually switches mixture control to open loop and suspends adaptation and converter monitoring.

Possible causes

Possible symptoms

Diagnosis

Use a compatible scan tool to confirm the code and check related codes and live data. Inspect the relevant wiring, connectors, power, ground and sensor signals using the vehicle manufacturer’s wiring diagram and service specifications. Do not replace a component based on the code alone.

Related DTC codes

Search this code in DTC Search

Generic OBD-II reference only. Manufacturer-specific definitions, test values and repair procedures can vary by vehicle. Verify with vehicle-specific service information.