P0151 – O2 Sensor Circuit Low Voltage Bank 2 Sensor 1
The oxygen sensor before the catalytic converter on bank 2 (sensor 1) is the main control sensor for the mixture. It is either a switching sensor (about 0.1 V lean to 0.9 V rich) or a wide-band sensor that works with a pump current evaluated by an interface chip. Bank 2 exists only on engines with two exhaust manifolds. P0151 is the bank 2 counterpart of P0131. On switching sensors the signal stays below about 40–50 mV in closed loop with a stoichiometric target (GM LT4: 285 of 350 samples; GM 3.0/3.6 V6 within 50 s); on wide-band sensors the interface chip reports a sensor wire shorted to ground. Two trips. A genuinely lean bank 2 shows up as P0174 rather than this code. A stored code usually switches mixture control to open loop and suspends adaptation and converter monitoring.
Possible causes
- Signal wire (or a wide-band sensor wire) shorted to ground, e.g. chafed on exhaust or gearbox
- Sensor faulty or poisoned (permanently lean signal)
- Large exhaust leak ahead of the sensor or misfires
- Connector wet or corroded
Possible symptoms
- Check engine light on
- Higher consumption, possibly rough running (no mixture control)
- Higher emissions, possible emissions test failure
- Possibly with P0174/P2197
Diagnosis
Use a compatible scan tool to confirm the code and check related codes and live data. Inspect the relevant wiring, connectors, power, ground and sensor signals using the vehicle manufacturer’s wiring diagram and service specifications. Do not replace a component based on the code alone.
Related DTC codes
Search this code in DTC Search
Generic OBD-II reference only. Manufacturer-specific definitions, test values and repair procedures can vary by vehicle. Verify with vehicle-specific service information.